00:00:26
rotating electrical Machinery is a part
00:00:28
of much military equipment
00:00:30
[Music]
00:00:38
whether it is a simple
00:00:39
[Music]
00:00:41
blower or a complicated electronic
00:00:43
device in a missile they all depend on
00:00:46
the proper functioning of rotating
00:00:48
electrical
00:00:52
equipment two types of motors and
00:00:54
generators are commonly in use
00:00:57
alternating current or AC
00:01:00
and direct current or DC motors and
00:01:05
generators this film will show the
00:01:07
principles governing the operation of DC
00:01:09
motors and
00:01:12
generators basic to the understanding of
00:01:14
DC motors and generators is the simple
00:01:17
generation of an electromotive Force an
00:01:20
EMF mechanical energy the moving of a
00:01:23
wire or conductor across a magnetic
00:01:25
field by hand in this instance produces
00:01:28
electrical energy
00:01:35
the magnetic field is composed of lines
00:01:38
of force as the conductor Cuts these
00:01:40
lines an electromotive force or EMF is
00:01:43
generated in the
00:01:46
conductor moving the conductor down
00:01:49
through the field makes the needle of a
00:01:51
voltmeter deflect one way which means
00:01:54
the EMF has One
00:01:57
Direction moving the conductor up
00:01:59
through the veh
00:02:00
produces the opposite deflection of the
00:02:02
needle the EMF has now changed
00:02:09
Direction moving the conductor back and
00:02:12
forth with the field does not make the
00:02:14
needle of the voltmeter deflect there is
00:02:16
no EMF because the conductor is not
00:02:19
cutting the
00:02:23
field to illustrate the direction of
00:02:26
current flow the conventional symbols
00:02:28
will be used current flowing in a
00:02:31
conductor away from us is represented by
00:02:34
a cross toward us by a DOT however
00:02:38
moving a conductor in and out of the
00:02:39
field in this straight reciprocal
00:02:41
fashion is awkward and
00:02:48
impractical a simple generator of EMF
00:02:51
can also be made by rotating a single
00:02:53
turn coil within a stationary magnetic
00:02:56
field of two magnets with opposite
00:02:58
polarity the Loop now in effect becomes
00:03:01
two conductors because both the top and
00:03:04
bottom sections cut magnetic lines
00:03:06
during
00:03:15
rotation since they cut lines of force
00:03:17
of opposite directions as they rotate
00:03:20
emfs of opposite polarity will be
00:03:22
generated in the conductors in order to
00:03:25
have current flow in this circuit
00:03:26
polarities of the two conductors must be
00:03:29
opposite
00:03:34
the amount of EMF generated at any
00:03:36
instant is determined by three factors
00:03:39
the strength of the magnetic field that
00:03:41
is the number of lines of force the
00:03:43
length of the conductor cutting the
00:03:45
lines of force and the velocity with
00:03:47
which the conductor is turning we can
00:03:49
determine the amount of instantaneous
00:03:51
EMF by a simple
00:03:55
formula the instantaneous EMF e
00:04:00
equals B the strength of the
00:04:03
Field Time L the length of the conductor
00:04:07
cutting lines of force times V the
00:04:10
velocity of the conductor an increase in
00:04:13
the number of lines of force or the
00:04:15
strength of the field increases the
00:04:17
instantaneous EMF in the
00:04:25
conductor increases in the length of the
00:04:27
conductor cutting lines also Al
00:04:29
increases the
00:04:33
EMF and finally the greater the velocity
00:04:36
of the conductor the greater the
00:04:41
EMF this formula assumes conductor
00:04:44
Motion in a straight line that is to say
00:04:47
cutting the same number of lines for
00:04:49
each increment of its motion but the
00:04:51
conductor in an actual machine is not
00:04:54
moving in a straight line but rotating
00:05:03
when the conductor moves in a rotary
00:05:05
path the number of lines cut varies
00:05:08
depending on the position of the
00:05:13
conductor at the top of the field for
00:05:15
instance no lines are being cut and no
00:05:18
EMF is
00:05:21
generated as the conductor keeps turning
00:05:24
the number of lines cut increases so
00:05:26
that at a quarter turn or 90° the
00:05:29
maximum number is being cut and maximum
00:05:32
EMF is
00:05:37
generated again at
00:05:39
180° no lines are cut no
00:05:45
EMF we reach a maximum again at
00:05:48
270° and finally again at 360° no lines
00:05:53
are cut the conductor has rotated 360
00:05:57
mechanical deg which correspond in this
00:06:00
instance to 360 electrical
00:06:05
de therefore when the conductor moves in
00:06:08
a rotary path another factor is added to
00:06:10
the original formula for the
00:06:12
determination of instantaneous EMF the
00:06:15
formula that now applies is
00:06:18
instantaneous EMF equals field strength
00:06:23
time the length of the
00:06:24
conductor time
00:06:27
velocity multiplied by sin Theta
00:06:34
Theta is the angle formed by the flux
00:06:37
line and the motion of the conductor the
00:06:39
number of lines cut and the amount of
00:06:41
EMF generated is proportional to the
00:06:44
sign of the angle formed by the magnetic
00:06:46
lines with a conductor
00:06:55
motion a graph of EMF versus conductor
00:06:59
position during one revolution will be a
00:07:01
sine wave representing alternating
00:07:03
current or AC all rotary generators
00:07:07
produce AC
00:07:14
internally what you have seen so far is
00:07:17
really the theory and operation of a
00:07:19
basic AC generator but our purpose was
00:07:22
to explain the principles of operation
00:07:24
of a DC generator to get direct current
00:07:28
we will attach each end of the the
00:07:29
conductor to a segment of copper forming
00:07:31
a commutator now our machine is a DC
00:07:35
generator the commutator rotates with
00:07:37
the
00:07:44
loop stationary contacts carbon brushes
00:07:48
ride on the commutator
00:07:52
segments they provide a means of
00:07:54
connecting a meter or any other load to
00:07:56
the generator the loop of a conductor
00:07:59
wound on a rotor and the commutator are
00:08:02
referred to as the Armature as the loop
00:08:05
revolves and the EMF in the conductor
00:08:07
reverses polarity the connections to the
00:08:10
load are also reversed and the current
00:08:12
flow will maintain the same direction
00:08:20
externally represented graphically the
00:08:23
output amplitude still varies the DC is
00:08:26
in the form of pulses it is a pulse
00:08:29
ating direct current or
00:08:31
PDC the pulsation from zero to maximum
00:08:35
twice for each revolution of the loop is
00:08:37
called Ripple this Ripple can be reduced
00:08:41
by adding more loops and more commutator
00:08:43
segments to the existing Armature two
00:08:46
Loops at right angles connected to four
00:08:48
commutator segments provide two outputs
00:08:50
instead of
00:08:57
one these out puts are 90° displaced or
00:09:01
apart which combined to smooth the DC
00:09:09
output however even with two loops and
00:09:12
four commutator segments the rectified
00:09:14
curve is still somewhat
00:09:20
irregular by adding magnets we increase
00:09:23
the number of fields cut by the Armature
00:09:26
as we increase the number of loops and
00:09:28
commutator segments the variation
00:09:30
between maximum and minimum value
00:09:37
decreases this in effect tends to
00:09:40
flatten the DC
00:09:47
output practical DC generator armatures
00:09:50
have a great many Loops wound on a
00:09:57
rotor the field is composed of many
00:10:00
electromagnets together these factors
00:10:02
tend to create an almost pure DC
00:10:07
output an important problem in the
00:10:09
design of generators is the prevention
00:10:11
of sparking between the commutator and
00:10:14
the brush assembly the prevention of
00:10:16
sparking depends on the position of the
00:10:20
brushes this line through points of zero
00:10:23
generated EMF is called the neutral plan
00:10:29
placing the brushes in this neutral
00:10:31
plane reduces the tendency for sparking
00:10:33
between brushes and commutator because
00:10:36
during the time a brush is touching both
00:10:37
commutator segments there is no
00:10:40
difference in potential between these
00:10:48
segments theoretically no sparking
00:10:51
should occur at the commutator brushes
00:10:52
when they are placed in this position
00:11:02
but the current flowing in the Armature
00:11:04
Loops or coils sets up a magnetic field
00:11:07
of its
00:11:12
own this magnetic field interacts with a
00:11:15
main magnetic field and distorts it the
00:11:17
Distortion causes a shift in the neutral
00:11:19
plane and sparking at the brushes the
00:11:22
effect is called armature reaction
00:11:30
sparking may cause severe interference
00:11:32
in nearby electronic
00:11:38
equipment there are two ways of
00:11:40
maintaining the neutral plane in its
00:11:42
correct position and thus avoiding
00:11:44
sparking it may be done by the
00:11:46
adjustment of the brush
00:11:53
position the brushes are adjusted to lie
00:11:55
in the adjusted neutral plane
00:12:05
the other way of maintaining the neutral
00:12:07
plane is by adding interpoles to the
00:12:09
generator field these interpoles are
00:12:11
small magnets placed between the poles
00:12:13
of the main field magnets the interpole
00:12:16
fields oppose the fields created by
00:12:18
armature
00:12:23
reaction the neutral plane is moved back
00:12:25
toward the correct position
00:12:40
in addition to further counteract
00:12:42
armature reaction windings called
00:12:44
compensating windings are sometimes
00:12:47
placed in the main pole faces the
00:12:49
current in these windings is armature
00:12:51
current flowing in opposite direction to
00:12:54
the current in the Armature conductors
00:13:04
magnetic fields in DC generators may be
00:13:07
produced by electromagnets or permanent
00:13:10
magnets permanent magnets are used in
00:13:13
relatively small devices like a field
00:13:15
telephone ringing
00:13:17
generator in larger generators the field
00:13:20
is created by
00:13:26
electromagnets the field winding used in
00:13:28
this DC generator can be represented by
00:13:31
a
00:13:32
symbol the symbol is that of an iron
00:13:35
core
00:13:38
inductor current to excite the field
00:13:40
windings can be supplied from an
00:13:42
external
00:13:43
Source in that case the generator is
00:13:46
classified as separately
00:13:52
excited a small part of the generator's
00:13:55
own output can also do the exciting in
00:13:58
that case it will be
00:13:59
a self excited generator self excited
00:14:02
generators must be initially
00:14:09
magnetized the residual magnetism in the
00:14:11
core of a field winding provides enough
00:14:14
magnetism to begin generator
00:14:16
[Music]
00:14:20
action the field coil winding may be
00:14:23
connected in several ways this is a
00:14:26
series wound generator which means the
00:14:28
field Co is in series with the Armature
00:14:31
because of this series Arrangement it
00:14:33
has poor voltage regulation the reason
00:14:36
for this can be demonstrated in the
00:14:37
following manner additional load will
00:14:40
cause more current to flow in the field
00:14:42
coil increase in field strength
00:14:45
increases voltage increase in voltage
00:14:49
causes more current to flow this
00:14:51
continuing action stops only when the
00:14:54
core is saturated
00:15:03
when the load is increased the voltage
00:15:05
will
00:15:07
increase when the load decreases voltage
00:15:10
will decrease voltage regulation in the
00:15:13
series wound generator therefore is very
00:15:20
poor when instead of in series The Field
00:15:23
winding is connected in parallel with
00:15:25
the Armature and the load we have a
00:15:27
shunt wound generat
00:15:32
now the field current is independent of
00:15:34
the load current therefore an increase
00:15:37
in Armature current will not cause an
00:15:39
increase in the voltage output voltage
00:15:42
regulation here is greatly
00:15:49
improved in shunt wound generators
00:15:51
therefore changing load causes
00:15:53
relatively small change in voltage
00:15:55
output
00:15:59
by changing the Armature winding a
00:16:01
compound wound generator results which
00:16:04
combines the best features of both types
00:16:07
the series and the shunt wound generator
00:16:09
when windings are arranged so that
00:16:12
magnetic fields oppose each other it
00:16:14
becomes in effect a series generator
00:16:17
this is used only where constant current
00:16:19
is the prime requirement such as in arc
00:16:22
welding by changing the magnetic
00:16:25
polarity of one of the fields the field
00:16:27
windings Aid one another as a result
00:16:30
this compound wound generator has good
00:16:32
voltage and fair current
00:16:39
regulation a graphic representation of
00:16:42
generator output characteristics with
00:16:44
terminal voltage plotted vertically and
00:16:47
Armature current horizontally would look
00:16:50
something like
00:16:52
this as we have seen in the output of
00:16:55
the series wound generator voltage
00:16:57
regulation is very poor in parallel or
00:17:00
shunt wound generators the voltage
00:17:03
regulation is fairly good but current
00:17:05
regulation is poor compound wound
00:17:08
generators offer a flat compounded
00:17:11
output that is normally most desirable
00:17:14
it combines the good features of both
00:17:16
the shunt and series wound generators
00:17:18
and provides stable voltage output under
00:17:21
changing
00:17:26
loads as we have seen in our analys of
00:17:29
the DC generator its primary function is
00:17:32
the conversion of mechanical energy to
00:17:34
electrical energy if we now reverse the
00:17:37
procedure and connect an electrical
00:17:40
power source to the
00:17:41
generator we have a DC motor instead of
00:17:44
a DC
00:17:49
generator motor action can be
00:17:51
illustrated by attaching a power source
00:17:53
to a conductor which is inside a
00:17:55
magnetic field the electric current
00:17:58
creates polarity in the conductor the
00:18:00
South Pole of the magnet attracts the
00:18:02
North Pole of the conductor and repels
00:18:05
the South Pole the North Pole of a
00:18:07
magnet attracts the South Pole of the
00:18:10
conductor and repels the North
00:18:14
Pole this creates movement depending on
00:18:17
the direction of the steady magnetic
00:18:23
field the movement also depends on the
00:18:26
direction of the current flow through
00:18:27
the wire
00:18:35
by changing the polarity of the battery
00:18:38
the conductor now moves in the opposite
00:18:47
direction to see what really happens
00:18:50
let's go to a drawing again here a
00:18:52
conductor is suspended in a magnetic
00:18:54
field current flow from a power source
00:18:57
creates its own magnetic field in and
00:18:59
around the
00:19:01
conductor this field around the
00:19:03
conductor reacts with a main magnetic
00:19:05
field to cause motion of the conductor
00:19:07
either out of the field or into it the
00:19:11
arrow point indicates the direction of
00:19:12
the current flow in the
00:19:18
conductor in this case the flow is
00:19:20
toward us the field of the conductor has
00:19:23
the same direction as the main field
00:19:25
above the conductor and the opposite
00:19:28
direction of of the field below the
00:19:30
conductor these two magnetic forces
00:19:32
added together distort the lines of the
00:19:34
main field upward the field above the
00:19:38
conductor is thus made stronger and the
00:19:40
field below the conductor is made
00:19:43
weaker so the conductor moves
00:19:50
down conversely when current flows in
00:19:54
the opposite direction that is to say
00:19:56
away from us the field of the conductor
00:19:58
opposes the main field above the
00:20:03
conductor this AIDS the main field below
00:20:06
the conductor distorting the lines down
00:20:09
the field below the conductor is thus
00:20:10
made stronger while the field above the
00:20:13
conductor is made relatively weaker this
00:20:15
forces the conductor to move
00:20:17
up with this basic principle of motor
00:20:20
action understood we can now examine the
00:20:22
DC
00:20:26
motor the basic DC motor like the DC
00:20:29
generator consists of a pair of magnetic
00:20:33
poles an Armature made up of a single
00:20:36
turn Loop a commutator and a brush
00:20:40
assembly as we have seen a conductor in
00:20:43
a magnetic field will move when a
00:20:44
voltage is applied to
00:20:48
it with a voltage applied and the
00:20:51
magnetic field and current flow as shown
00:20:53
the right conductor will be pushed down
00:20:56
while the left one is pushed up since
00:20:59
the forces on each conductor are now in
00:21:01
exact balance there will be no more
00:21:08
motion adding another loop and two
00:21:10
commutator segments ensures that at no
00:21:13
time will balancing forces cancel each
00:21:15
other
00:21:17
out with this setup there will be motion
00:21:20
at all
00:21:23
times as one commutator segment has
00:21:25
moved away from the brushes another now
00:21:28
takes its place and the movement
00:21:29
continues the greater the number of
00:21:31
Loops in the Armature the smoother its
00:21:35
motion for this reason rotors in
00:21:38
Practical DC motors have many
00:21:41
Loops since current in the rotor Loops
00:21:44
must reverse each half cycle two
00:21:46
commutator segments per Loop are
00:21:51
required here in the motor as in the DC
00:21:54
generator there is a neutral plane the
00:21:57
interaction of a conductor fields on the
00:21:59
main field causes this neutral plane to
00:22:01
shift and sparking to occur when a load
00:22:04
is
00:22:09
added sparking in DC motors also
00:22:12
produces burned commutators and
00:22:14
interference in nearby electronic
00:22:16
equipment this sparking can be prevented
00:22:18
in one of two
00:22:21
ways one is by the adjustment of the
00:22:23
brush
00:22:26
position the brushes are moved until
00:22:29
they lie in the adjusted neutral
00:22:35
plane in the motor as in the generator
00:22:38
small interpoles between the poles of
00:22:40
the main magnets are also used to
00:22:42
eliminate the shift of the neutral
00:22:46
plane these interpole fields tend to
00:22:48
oppose the fields created by armature
00:22:51
reaction the neutral plane is moved back
00:22:53
toward its correct position also aiding
00:22:56
our compensating windings which carry
00:22:59
Armature current in the opposite
00:23:00
direction to the current in the Armature
00:23:03
conductors the neutral plane is thus
00:23:05
maintained in its proper
00:23:13
position DC motors operate most
00:23:16
efficiently when sparking is
00:23:22
eliminated we saw earlier that when a
00:23:24
conductor is moved by mechanical energy
00:23:26
in a magnetic field and EMF is generated
00:23:30
this is generator
00:23:35
action in the DC motor when rotation is
00:23:38
desired it is necessary to apply an EMF
00:23:42
to the conductor however when used as a
00:23:44
motor an opposing EMF is also generated
00:23:47
in the
00:23:51
conductor this is called the counter
00:23:54
electromotive force or
00:23:56
cemf by lenses Lo
00:23:59
the generated cemf must oppose the
00:24:02
applied
00:24:05
EMF the amount of CF depends on the
00:24:08
speed of rotation this is of practical
00:24:11
importance in large
00:24:15
Motors when starting large Motors the
00:24:18
problem exists of limiting current
00:24:20
through the rotor windings until a CF
00:24:23
can be built up if the full current is
00:24:25
applied before the CF develops it may
00:24:28
burn out the rotor
00:24:32
windings starting boxes are used with DC
00:24:35
motors in order to avoid this
00:24:37
application of current before the cemf
00:24:40
is built
00:24:48
up here is a basic shunt motor with its
00:24:51
starting
00:24:55
box in the starting position the circuit
00:24:58
to the rotor windings is closed through
00:25:00
a series of large resistance
00:25:04
coils as the lever of the switch is
00:25:06
moved rotor speed and CF build up
00:25:09
gradually and the resistance coils are
00:25:12
subsequently cut out until running speed
00:25:14
has been reached the lever is held in
00:25:16
the fully open position by an
00:25:19
electromagnet if for any reason the
00:25:21
power should fail or the field coil open
00:25:24
the electromagnet becomes deenergized
00:25:26
and the lever is returned to the
00:25:28
starting position by Spring
00:25:35
action just as in DC generators DC
00:25:39
motors seldom use permanent magnets for
00:25:41
the field instead electromagnets are
00:25:44
used like with a DC generator field
00:25:47
windings are constructed in several ways
00:25:50
each type of winding has special
00:25:52
characteristics special values and
00:25:54
specific uses
00:26:00
the series wound motor has good starting
00:26:02
torque or turning Force torque depends
00:26:05
on Armature current and on field
00:26:12
strength since field strength is
00:26:14
proportional to current the high
00:26:17
starting current before CF is developed
00:26:20
affects torque as the square of the
00:26:23
current the motor begins to turn
00:26:26
attempting to develop enough CF to
00:26:29
completely oppose the applied
00:26:33
EMF the load prevents this acting to
00:26:37
control the speed of the motor but if
00:26:39
the load is suddenly removed like in the
00:26:42
case of a broken belt the motor will
00:26:44
build up speed trying to develop more CF
00:26:48
until it destroys
00:26:55
itself the shunt wound motor has less
00:26:58
starting torque but it is less dependent
00:27:00
on load for speed
00:27:04
control in the shunt wound motor the
00:27:07
field coils are connected in parallel
00:27:09
directly across the DC input
00:27:14
terminals the starting torque is not as
00:27:17
great as in the series motor since field
00:27:19
strength is not affected by Armature
00:27:25
current the speed of a shunt motor isir
00:27:28
L constant under conditions of changing
00:27:30
load as more load is applied the speed
00:27:33
of the Armature decreases this decreases
00:27:36
the CF and increases the current
00:27:44
input the increase in current input
00:27:48
boosts the coupling between the Field
00:27:49
and Armature and increases the torque
00:27:52
causing the motor to resume approximate
00:27:54
running speed
00:27:58
a sudden reduction in load will not
00:28:00
damage the motor because the field
00:28:02
current is independent of rotor current
00:28:04
in the shunt wound
00:28:08
motor the desirable characteristics of
00:28:11
both the series and shant wild Motors
00:28:13
can be achieved in the compound wound
00:28:15
motor in order to obtain good starting
00:28:18
torque the series field is used when
00:28:20
running speed has been attained a
00:28:22
centrifugal switch cuts out the series
00:28:25
field and cuts in the shunt field it is
00:28:28
now a shunt motor and the speed
00:28:30
regulation is
00:28:36
good compounding provides good starting
00:28:39
torque and good speed regulation this
00:28:42
allows for efficient operation and
00:28:44
minimizes the possibility of damage to
00:28:46
the
00:28:50
motor now for a quick summary the
00:28:53
operation of all rotating electrical
00:28:55
Machinery is based on one simple
00:28:57
principle the generation of an
00:29:01
EMF the principle is used in the
00:29:03
construction of a simple AC generator
00:29:06
the generator output e or instantaneous
00:29:11
EMF equals B strength of
00:29:14
Field Time L length of the
00:29:19
conductor time V velocity of the
00:29:24
conductor but because the movement of
00:29:26
the conductor in the field is actually
00:29:28
circular we must also multiply with a
00:29:31
sign of the angle formed by the lines of
00:29:33
force and motion of the conductor in
00:29:36
order to arrive at the
00:29:43
EMF all generators are basically
00:29:46
alternating current generators and
00:29:48
produce AC
00:29:55
internally the basic AC generator
00:29:58
becomes a DC generator when a commutator
00:30:01
is attached to the
00:30:06
conductor each commutator segment
00:30:09
rotates with its respective conductor
00:30:11
producing a direct
00:30:17
current this current which is a
00:30:19
pulsating current is made Smoother by
00:30:22
the addition of more magnets and more
00:30:24
loops
00:30:33
sparking in a generator is sometimes
00:30:35
caused by a shift in the neutral plane
00:30:38
this can be corrected by adjusting the
00:30:40
brush
00:30:45
position or by the use of interpoles and
00:30:48
compensating
00:30:55
windings current for field Landings may
00:30:58
be supplied from an outside Source in
00:31:01
which case the generator will be
00:31:02
separately excited or the current may be
00:31:05
a part of the generator's own output in
00:31:08
which event it is called self
00:31:14
excited generator field windings are
00:31:16
constructed in three ways series W where
00:31:20
the field windings and the Armature are
00:31:21
in
00:31:24
series shunt wound in which the field
00:31:27
winding is in parallel with the Armature
00:31:29
and the
00:31:33
load and compound wound in which the
00:31:36
best features of both the shunt and
00:31:38
series wild generators are
00:31:43
combined voltage regulation in the
00:31:45
series wild generator is poor in the
00:31:48
shunt wild generator voltage regulation
00:31:50
is fairly good but current regulation is
00:31:53
poor compound wound generators provide
00:31:56
stable voltage under changing load
00:31:58
this output is normally most
00:32:05
desirable motor action is the opposite
00:32:08
of generator procedure in a DC motor
00:32:11
voltage is applied to two or more Loops
00:32:13
in a magnetic field this causes polarity
00:32:16
in the loops the interaction of this
00:32:19
polarity with the polarity of the field
00:32:21
makes the loops
00:32:24
rotate this is the basic DC motor when
00:32:28
the conductor of the motor is rotated by
00:32:30
an applied EMF it also generates a
00:32:33
counter electromotive Force according to
00:32:35
lens's law this generated cemf must
00:32:39
oppose the applied
00:32:43
EMF as in generators field windings and
00:32:46
DC motors are of three types the series
00:32:49
wound motor has good starting torque but
00:32:52
since its only governing factor is the
00:32:54
load the speed regulation is poor
00:33:01
if the load is disengaged suddenly the
00:33:03
motor will race to
00:33:07
destruction in shun wound motors with
00:33:10
the field coils connected in parallel
00:33:12
across the DC input terminals the
00:33:14
starting torque is not too good but
00:33:17
since the field current is independent
00:33:19
of the rotor current the speed
00:33:20
regulation is quite good
00:33:28
the compound wound motor combines the
00:33:30
best features of both types it uses a
00:33:32
series section for good starting
00:33:36
torque then it switches to a shunt
00:33:39
arrangement for good speed
00:33:48
regulation DC electrical motors and
00:33:50
generators are at the heart of much
00:33:53
military equipment a proper
00:33:55
understanding of them is therefore
00:33:57
important